Cables

Back to TopBack to Top

Shielded Twisted Pair Cable (FUTP), Category 6A, 4 Pair, Solid, Riser, Indoor

Part no. FUTP4-C6A-SOLID-CMR-XX-305

Quantity:

Physical & Electrical Characteristics (at 20°C)

Temperature & voltage rating 75°C / 300V
Spark test 2.5 KV DC
AC leakage current through overall jacket _ 10mA (1.5KV AC)
Cable cold bend -20°C for 4 hr
Conductor DC resistance _ 9.38 _/100m
Resistance unbalance _ 5%
Dielectric strength 1.5 KV ac for 2 s
Insulation resistance _ 5000 M_•Km
Mutual capacitance _ 5.6 nF/100m
Capacitance unbalance pair-to-ground _ 330 pF/100m
Conductor Material 24AWG solid bare copper
Insulation Material of single layer Fluorinated Ethylene Propylene (FEP)
Color code & diameter Blue & white/blue Stripe 0.85 ± 0.02 mm
Material of dual layer Polyolefin (PO)
Fluorinated Ethylene Propylene (FEP)
Color code & diameter Orange & white/orange stripe 0.86 ± 0.02 mm
Green & white/green stripe 0.87 ± 0.02 mm
Brown & white/brown stripe 0.86 ± 0.02 mm
Twisted Description Left hand direction
Assembly Description Left hand direction
Rip cord Material Polyester multi-yarn
Jacket Material Low smoke flame retardant polyvinyl chloride (LSFRPVC)
Diameter 4.5 ± 0.2 mm
Thickness 0.38 ± 0.03 mm
Color Per customer`s request
Marking Hyperline UTP4-C5E-SOLID-CMR-XX-305 — E303448 U/UTP 4PR 24AWG C(UL)US CMR — ETL VERIFIED TO ANSI/TIA-568 C.2 CAT 5E 350MHz WW/YY1 XXXXFT-ANote 1: WW/YY is date code.

 

  • High performance of transmission.
  • High quality of safety property.
  • Sweep frequency up to 500 MHz.

Application

  • Structure cabling for horizontal and building backbone cable.
  • Transmission of digital and analogue for data, video and audio applications.
  • Overall metal shielded providing good protection from EMI noise.
  • IEEE 802.3an 10GBASE-T and legacy speeds.
  • CDDI / ATM / Token Ring
  • IEEE 802.3af (PoE) / IEEE 802.3at (PoE+)

Applicable Standard

  • Electrical Transmission
    • ANSI/TIA-568-C.2 (2009)
    • ISO/IEC 11801 (Edition 2.2)
    • IEC 61156-5 (Edition 2.0)
  • Flame Test
    • UL 1666 (CMR)
  • Material and Construction
    • UL 444
    • CSA 22.2 NO.214
  • EU Directive 2011/65/EC (RoHS2)
  • EU Directive 2006/95/EC (LVD)
  • CE compliance date: 2010.01.01

Usage & Environmental Condition

Temperature range Storage & shipping -20°C to 75°C
Installation 0°C to 60°C
Operation -20°C to 60°C
Minimum bending radius _ 4 times of overall diameter
Maximum pulling tension _ 110 N