Physical & Electrical Characteristics (at 20°C)

Temperature & voltage rating 75°C / 300V
Spark test 2.5 KV DC
AC leakage current through overall jacket _ 10mA (1.5KV AC)
Cable cold bend -20°C for 4 hr
Conductor DC resistance _ 9.38 _/100m
Resistance unbalance _ 5%
Dielectric strength 1.5 KV ac for 2 s
Insulation resistance _ 5000 M_•Km
Mutual capacitance _ 5.6 nF/100m
Capacitance unbalance pair-to-ground _ 330 pF/100m
Conductor Material 23AWG solid bare copper
Insulation Material Fluorinated Ethylene Propylene (FEP)
Color code & diameter Blue & white/blue Stripe 1.10 ± 0.02 mm
Orange & white/orange stripe 1.06 ± 0.02 mm
Green & white/green stripe 1.09 ± 0.02 mm
Brown & white/brown stripe 1.06 ± 0.02 mm
Twisted Description Left hand direction
Filler Material Fluorinated Ethylene Propylene (FEP)
Assembly Description Left hand direction
Shield Material Mylar tape
Drain wire Material 24AWG solid tinned copper
Shield Material Al Mylar tape
Description 100 % coverage and mylar side facing out
Jacket Material Low smoke flame retardant polyvinyl chloride (LSFRPVC)
Diameter 7.00 ± 0.2 mm
Thickness 0.45 ± 0.05 mm
Color Per customer`s request
Marking Hyperline FUTP4-C6A-SOLID-CMP-XX-305—E303448 F/UTP 4PR 23AWG C(UL)US CMP—ETL VERIFIED TO ANSI/TIA-568-C.2 CAT 6A 500MHz WW/YY1 XXXXFT-A
Note 1: WW/YY is date code.
  • High performance of transmission.
  • High quality of safety property.
  • Sweep frequency up to 500 MHz.

Application

  • Structure cabling for horizontal and building backbone cable.
  • Transmission of digital and analogue for data, video and audio applications.
  • Overall metal shielded providing good protection from EMI noise.
  • IEEE 802.3an 10GBASE-T and legacy speeds.
  • CDDI / ATM / Token Ring
  • IEEE 802.3af (PoE) / IEEE 802.3at (PoE+)

Applicable Standard

  • Electrical Transmission
    • ANSI/TIA-568-C.2 (2009)
    • ISO/IEC 11801 (Edition 2.2)
    • IEC 61156-5 (Edition 2.0)
  • Flame Test
    • NFPA 262 (CMP)
  • Material and Construction
    • UL 444
    • CSA 22.2 NO.214
  • EU Directive 2011/65/EC (RoHS2)
  • EU Directive 2006/95/EC (LVD)
  • CE compliance date: 2010.01.01
Temperature range Storage & shipping -20°C to 75°C
Installation 0°C to 60°C
Operation -20°C to 60°C
Minimum bending radius _ 4 times of overall diameter
Maximum pulling tension _ 110 N